Mouse Angiotensin Converting Enzyme Receptor ELISA

Mouse Angiotensin Converting Enzyme Receptor ELISA Kit Instructions for Use This kit is for research use only.

Drug Name:
Generic name: Mouse Angiotensin Converting Enzyme Receptor ELISA Diagnostic Kit

purpose of usage:
This kit is used to determine the content of angiotensin-converting enzyme receptors in serum, plasma, or other relevant tissue fluids of mice and mice.

Experimental principle:
This kit uses the double antibody sandwich method to determine the level of mouse angiotensin converting enzyme receptor in the specimen. Microporous plates were coated with purified mouse angiotensin-converting enzyme receptor antibody to make solid-phase antibodies, and mouse angiotensin-converting enzyme receptor antigen was added to the microwells coated with monoclonal antibody in turn, and then labeled with HRP The angiotensin-converting enzyme receptor antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the mouse angiotensin converting enzyme receptor in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of mouse angiotensin converting enzyme receptor antigen in the sample was calculated by a standard curve.

Kit composition:
1 20 times concentrated washing solution 50ml × 1 bottle 7 stop solution 6ml × 1 bottle
2 Enzyme label reagent 6ml × 1 bottle 8 standard (225 ng / L) 0.5ml × 1 bottle
3 Enzyme label coating plate 12 well × 8 strips 9 standard dilution 2ml × 1 bottle
4 Sample diluent 6ml × 1 bottle 10 instructions 1 copy
5 Developer A solution 6ml × 1 bottle 11 2 sealing film
6 Developer B liquid 6ml × 1 / bottle 12 sealed bag 1

Specimen requirements:
1. Experiment as soon as possible after specimen collection.
2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
3. The specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

Steps:
1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of the standard products in the first and second wells, and then add the standard products in the first and second wells. 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard dilution solution to the third and fourth wells respectively, mix well Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells respectively. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentration is (150 ng / L, 100ng / L, 50 ng / L, 25ng / L, 12.5 ng / L).
2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the test sample (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes.
4. Mixing solution: Dilute 25 times concentrated washing liquid with distilled water 25 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing solution, let it stand for 30 seconds and discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: Add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop for 15 minutes in the dark at 37 ℃.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Calculation:
Taking the concentration of the standard as the abscissa (logarithmic coordinate) and the OD value as the ordinate (ordinary coordinate), draw a standard curve on the graph paper, and find out the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by Dilution factor; or calculate the linear regression equation of the standard curve using the concentration and OD value of the standard, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.

Precautions:
1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than 1.5 times the OD value of the standard pores), please dilute it with a certain multiple of the sample diluent (n times) before measuring, and finally multiply the total dilution factor (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. The determination of the test results must be based on the reading of the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.

examination range:
10ng / L -200ng / L

specification:
96 servings / box

Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months

The Inport Stopper For I.V Fluid Bag is based on the polycarbonate joint formed by injection molding process, comprising of the injection‐purpose halogenated butyl rubber stopper and outer cap. Among which, the material for polycarbonate joint is the imported medical‐level polycarbonate, complying with the FDA rules; the injection‐purpose halogenated butyl rubber stopper can be chosen to use the well‐known domestic product or imported product on the request of user.

The medicine‐loading stopper is produced in the clean plant, with the partial part reaching to Class 100 under the Class 10,000 background. The main working procedures, such as the injection molding, inspection and cleaning, and assembly and etc., are designed and processed as per the cleanliness requirements at the partial level of Class 100, which passes the GMP on‐site certification and complies with the cleanliness requirements of high capacity injection medicine.

 The main production equipments, test and inspection instruments of medicine‐loading stopper have already reached to the international level and are advanced at home. Meanwhile, the full production process is conducted the strict control and management, and making product free of plasticizing agent, loading agent and lubricating agent, and free of absorption or transfer when contacting with liquid medicine, neither the pyrogen and soluble matter, thence such equipments may ensure the product quality.

The inport stopper for I.V fluid bag is mainly used for double‐hose non‐PVC soft bag.

Inport Stopper For I.V Fluid Bag

I.V Fluid Bag Inport Stopper,Infusion Bag Medical Inport Stopper,Fluid Bag Stopper

YANGZHONG HONGYUN BOTTLE CAPS MAKING FACTORY , https://www.hongyunyz.com