Rat Creatine Kinase Isozyme (CK-MB) ELISA Kit
Rat Creatine Kinase Isozyme (CK-MB) ELISA Kit (Used in serum, plasma, cell culture supernatant and other biological fluids) principle This experiment uses the double antibody sandwich ABC-ELISA method. The anti-rat CK-MB monoclonal antibody was coated on the enzyme labeling plate. The CK-MB in the standard and the sample was combined with the monoclonal antibody, and the biotinylated anti-rat CK-MB was added to form an immune complex and connected to the plate On the top, the horseradish peroxidase-labeled Streptavidin is combined with biotin, the substrate working solution is added, the blue is added, and finally the stop solution sulfuric acid is added. The OD value is measured at 450nm. The CK-MB concentration is proportional to the OD value, which can be passed Draw a standard curve to find the CK-MB concentration in the specimen. Kit composition (stored at 2-8 ° C) Coated Wells 96 wells Enzyme Conjugate 12ml 10 × Sample Buffer 12ml 20 × concentrated washing solution (Wash Buffer) 50ml Standards (Standards): 4000ng / bottle 2 bottles Substrate working solution (TMB Solution) 12ml The first antibody working solution (Biotinylated Antibody) 12ml Stop Solution (Stop Solution) 12ml Prepare reagents and collect blood samples 1. Collect specimens: serum, plasma (EDTA, citrate, heparin anticoagulation), cell culture supernatant, tissue homogenate, etc. as soon as possible, stored at 2-8 ℃ for 48 hours; longer time must be frozen (-20 ℃ Or -70 ℃), avoid repeated freezing and thawing. Serum and plasma should be diluted at least 1: 5 (take 20ul, add specimen diluent 80ul, and dilute 5 times). 2. Preparation of standard solution: add 2ml of distilled water to mix well before use to make a solution of 2000ng / ml. Set 8 standard tubes, add 900ul of sample dilution in the first tube, and 500ul of sample dilution in the second to eighth tubes. In the first tube, add 100 ul of the standard solution of 2000 ng / ml, mix it, and then aspirate 500 ul with the pipette, and move to the second tube. Repeat the dilution in this manner repeatedly, draw 500ul from the seventh tube and discard it. The eighth tube is a blank control. 3. The 10 × specimen dilution is diluted 1:10 with distilled water (example: 1ml concentrated dilution + 9ml distilled water). 4. Washing solution: 1:20 dilution with redistilled water (example: 1ml concentrated washing solution is added with 19ml of redistilled water) Testing procedures 1. Add sample: add 100ul of standard or sample to be tested to each well, mix the reaction plate thoroughly and place at 37 ℃ for 120 minutes. 2. Wash the plate: wash the reaction plate 4-6 times with the washing solution, and print it on the filter paper. 3. Add 100ul of the first antibody working solution to each well. The reaction plate was mixed thoroughly and then placed at 37 ° C for 60 minutes. 4. Wash board: same as above. 5. Add 100ul of enzyme-labeled antibody working solution to each well. Place the reaction plate at 37 ° C for 30 minutes. 6. Wash board: same as above. 7. Add 100ul of substrate working solution to each well, and place in a dark place at 37 ℃ for 15 minutes. 8. Add 100ul of stop solution to each well and mix well. 9. Measure absorbance at 450nm with a microplate reader within 30 minutes. Result calculation and judgment 1. All OD values ​​should be calculated after subtracting the blank value. 2. Take the standard products 200, 100, 50, 25, 12.5, 6.25, 3.12, 0 ng / ml as the abscissa, and the OD value as the ordinate. 3. Find the corresponding CK-MB content on the graph according to the OD value of the sample, and then multiply it by the dilution factor. Kit performance 1. Sensitivity: The smallest CK-MB detection concentration is less than 1.6ng / ml. 2. Specificity: simultaneous detection of recombinant or natural rat CK-MB. Does not cross-react with other cytokines in rats. 3. Repeatability: The coefficient of variation within the board and the board is less than 10%. Precautions 1. The above standard holes and samples to be tested are recommended to be re-holes, and the standard curve should be made at the same time for each measurement. 2. The washing process is critical. Insufficient washing will lead to an increase in accuracy error and OD value. 3. After opening the slats, the remaining slats should be sealed again to keep the slats dry. 4. This kit should be stored in a 4oC refrigerator. 5. This kit is for scientific research only, not for clinical diagnosis!
multi-purpose basket:clothing,toys,sudries etc
large capaciy storage: consistent quality,longer use
say goodby to messy,enjoy simple life
It is our key belief that our workers and management staff complete all business with honesty,quality and responsibility in mind.With these principles firmly in place,we welcome clients from all over the world to establish a life time business relationship with us,as well as the people of insight to join our team for a bright future.
Plastic Bucket,Plastic Bucket With Lid,Plastic Pail,Small Plastic Buckets
Ningbo Meidai Import & Export Co.,Ltd , https://www.ningbomeidai.com